Producción Científica Profesorado

Potentiometric Behavior of Diverse Polypyrrolesulphate Films Electro Synthesized on Graphite Epoxy Resin Composite



Páez Hernández, María Elena

2009

J. Licona-Sánchez, T., Álvarez-Romero, G. A. Palomar-Pardavé, M., Galán-Vidal. C.A., Páez-Hernández, M.E. Potentiometric Behavior of Diverse Polypyrrolesulphate Films Electro Synthesized on Graphite Epoxy Resin Composite ECS Transactions, 20:1 (2009) 31-40. http://dx.doi.org/10.1149/1.3268370


Abstract


In this work, polypyrrole films are electrosynthesized in aqueous media over graphite-epoxy resin composite; sulphate ions used to dope the polymer are obtained from different salts (Na2SO4, Li2SO4, (NH4)2SO4 and K2SO4). Potentiostatic techniques are used to induce the polymerization. Potentiometric response of Ppy-SO4-2 films was evaluated by calibration curves. Analyzing the slope sign, behavior of the different films can be classified in three responses: anionic, cationic and anionic-cationic. These behaviors were observed for all synthesized films, independently of the sulphate salt used. When analyzing the transients obtained for the different salts, similarities where found for those with the same potentiometric behavior, but significative differences where observed when comparing transients of different potentiometric response. It was determined that the cation size of the sulphate salt influences the Ppy-SO4-2 film response. Boundaries on the potentiostatic synthesis parameters are suggested to induce a specific potentiometric response.



Producto de Investigación




Artículos relacionados

Silver and Silver Chloride Electrodeposits, an Alternative in the Construction of Ag/AgCl Solid Elec...

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Potentiometric Behavior of Diverse Polypyrrole-sulphate Films Electro Synthesized on Graphite - Epox...

Design and Construction of Solid State Ag/AgCl Reference Electrodes Through Electrochemical Depositi...

Evaluación del contenido de metales y su efecto en la estabilidad de antocianinas

Mercury Ions Removal from Aqueous Solution Using an Activated Composite Membrane

Nucleation and Growth Kinetics of Electrodeposited Sulfate-Doped Polypyrrole: Determination of the D...

Construction and Evaluation of a Gold Tubular Electrode for Flow Analysis: Application to Speciation...

Prevalence and Antimicrobial Resistance Patterns of Salmonella from Different Raw Foods in Mexico

Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5...