Producción Científica Profesorado

Voltammetric Quantification of Diclofenac Using a Modified CPE Enriched With TiO2 Nanoparticles and MWCNT



Alvarez Romero, Giaan Arturo

2021

Miriam Franco-Guzmán, Luis Humberto Mendoza-Huizar, Gabriela Roa-Morales, Carlos Andrés Galán-Vidal and Giaan Arturo Álvarez-Romero, Voltammetric Quantification of Diclofenac Using a Modified CPE Enriched With TiO2 Nanoparticles and MWCNT. J. Electrochem. Soc., 2021, 168, 037502


Abstract


This work describes the development of a voltammetric methodology based on a carbon paste electrode enriched with multiwalled carbon nanotubes and TiO2 nanoparticles, for the electrochemical quantification of diclofenac. All stages of the methodology were optimized by a Box-Behnken experimental design. The electrochemical behavior of diclofenac was studied by cyclic voltammetry. Results showed that the oxidation of diclofenac is favored by the presence of both MWCNT and TiO2 nanostructures since a considerable increase in the anodic peak current is observed when compared to a that obtained with a bare carbon paste electrode. Under the optimal values found and with the appropriate statistical analysis, a LOD of 0.33 ?M, a LOQ of 1.11 ?M, a linear concentration range from 1.1 × 10?6 to 5 × 10?3 M (R2 = 0.9958), and a sensitivity of 0.487 ?A.?M?1 were found. The electrode's response was precise as the reproducibility resulted to be 4.39% (%RSD). Finally, a study of possible interferences was performed, along with the quantification of diclofenac in pharmaceutical samples by the proposed voltammetric methodology. The voltammetric method was validated by comparing the results with those obtained with the UV?vis spectrophotometric method.






Artículos relacionados

Development of a Polypyrrole Selective Membrane For The Potentiometric Quantification of Saccharinat...

Characterization of Main Anthocyanins Extracted from Pericarp Blue Corn by MALDI-ToF MS

Determination of primary amino acids in wines by high performance liquid magneto-chromatography

Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5...

Evaluación del contenido de metales y su efecto en la estabilidad de antocianinas

Metal content evaluation and its effect on the stability of anthocyanins

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...

Influence of the Cation Nature of the Sulphate Salt on the Electrochemical Synthesis of Sulfate-Dope...

Magnetic solids in analytical chemistry: A review

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...