Producción Científica Profesorado

Large?volume sample stacking with polarity switching for analysis of azo dyes in water samples by capillary electrophoresis



Ibarra Ortega, Israel S.

2019

J. Francisco Flores-Aguilar, Lorena C. Medrano, Emmanuel Perez-Escalante, Jose A. Rodriguez, Rosa L. Camacho-Mendoza & Israel S. Ibarra (2019) Large?volume sample stacking with polarity switching for analysis of azo dyes in water samples by capillary electrophoresis, International Journal of Environmental Analytical Chemistry, 99:13, 1255-1267, DOI: 10.1080/03067319.2019.1618461


Abstract


A simple, fast and efficient on-line pre-concentration method (large-volume sample stacking) by capillary electrophoresis was proposed for determination of azo dyes residues (allura red [AR], sunset yellow [SY] and tartrazine [TAR]) in water samples. Pre-concentration variables involved in the system were optimised using of a Box?Bhenken design. Under the optimal conditions: injection time 150.0 s, pre-concentration time 120.0 s and reverse potential ?8.0 kV, the proposed methodology improved the analytical sensibility achieving limits of detection of 21.0?41.4 g L?1 with enrichment factors of 82.1?210.8 fold. The large-volume sample stacking-capillary electrophoresis method was validated and applied to determine azo dyes residues in 20 water samples (bottled, spring and tap water). Two samples were positive for sunset yellow and tartrazine with a concentration of 25.3 and 30.2 g L?1 and % RSD less than 10.0% in all cases.



Producto de Investigación




Artículos relacionados

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...

Evaluación del contenido de metales y su efecto en la estabilidad de antocianinas

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...

Construction and Evaluation of a Gold Tubular Electrode for Flow Analysis: Application to Speciation...

Presence and antimicrobial resistance of Escherichia coli isolated from foodstuffs in Hidalgo State ...

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Prevalence and Antimicrobial Resistance Patterns of Salmonella from Different Raw Foods in Mexico

Development of a novel nitrate-selective composite sensor based on doped polypyrrole

Determination of oxytetracycline in milk samples by polymer inclusion membrane separation coupled to...

Design and Construction of Solid State Ag/AgCl Reference Electrodes Through Electrochemical Depositi...