Producción Científica Profesorado

Magnetic solid phase extraction followed by high-performance liquid chromatography for the determination of sulphonamides in milk samples



Ibarra Ortega, Israel S.

2015

I.S. Ibarra, J.M. Miranda, J.A. Rodriguez, C. Nebot, A. Cepeda. Magnetic solid phase extraction followed by high-performance liquid chromatography for the determination of sulphonamides in milk samples. Food Chemistry 157 (2014) 511-517DOI: 10.1016/j.foodchem.2014.02.069


Abstract


A simple and effective method based on magnetic solid-phase extraction combined with high performance liquid chromatography was used for the determination of nine sulphonamides in milk samples. The extraction and cleanup via silica-based magnetic adsorbent dispersion in milk samples followed by the magnetic isolation and desorption of the analytes using NaOH?methanol. Three different magnetic phenyl silica adsorbents were synthesized by varying the molar ratio of phenyltrimethylsilane and tetramethylorthosilicate; these adsorbents were evaluated for sulphonamides retention in terms of their pH and degree of hydrophobicity. The optimal conditions were a pH of 6.0 and a magnetic:sorbent ratio of 2:1. Under optimal conditions, limits of detection ranging from 7 to 14 ?g L?1 were obtained. The method was validated according with the European Commision Decision 2002/657/EC. The proposed method was applied to analyse sulphonamides in 27 milk samples of different brands. Thirteen samples tested were positive for the presence of sulphonamides.



Producto de Investigación




Artículos relacionados

Characterization of Main Anthocyanins Extracted from Pericarp Blue Corn by MALDI-ToF MS

Validation of a tubular bismuth film amperometric detector: Determination of diclofenac sodium by mu...

Potentiometric Behavior of Diverse Polypyrrole-sulphate Films Electro Synthesized on Graphite - Epox...

Characterization of Main Anthocyanins Extracted from Pericarp Blue Corn by MALDI-ToF MS

Silver and Silver Chloride Electrodeposits, an Alternative in the Construction of Ag/AgCl Solid Elec...

Determination of oxytetracycline in milk samples by polymer inclusion membrane separation coupled to...

Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5...

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...

High-performance liquid magneto-chromatography

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...