Producción Científica Profesorado

Phenol Removal Process Development from Synthetic Wastewater Solutions Using a Polymer Inclusion Membrane.



Páez Hernández, María Elena

2013

Perez-Silva, I; Galan-Vidal, CA; Ramirez-Silva, MT ;Rodriguez, JA; Alvarez-Romero, GA; Paez-Hernandez, ME., Phenol Removal Process Development from Synthetic Wastewater Solutions Using a Polymer Inclusion Membrane. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, Año 2013 Volume: 52 Issue: 13 Pages: 4919-4923 DOI: 10.1021/ie3034569 ISSN: 0888-5885


Abstract


This paper presents the results concerning the first use of a polymer inclusion membrane (PIM) for the removal and transport of phenol from an aqueous solution and polluted water. The PIM contains Cyanex 923 as the carrier, cellulose triacetate (CTA) as the base polymer, and o-nitrophenyl pentyl ether (ONPPE) as a plasticizer. The effects of variables on the transport percentage of phenol have been studied. These variables include the concentration of the carrier and the plasticizer in the membrane, pH of the aqueous phase, and the concentration of NaOH in the stripping phase. This study shows that PIM composition has a great influence in phenol recovery, while the pH of the feed phase is a determining factor for the transport of phenol. In optimal conditions (PIM: 1 cm3 ONPPE/g CTA, 0.5 M of Cyanex 923; feed phase: pH 2; stripping phase: NaOH 0.25 M), it is possible to transport 85% of phenol present in both the water lab feed phase and polluted water. Chemical oxygen demand (COD) shows that only 4.3% of organic compounds other than phenol are transported to the stripping phase, which indicates that the process is highly discriminative for phenol, even in extremely contaminated water.



Producto de Investigación




Artículos relacionados

Silver and Silver Chloride Electrodeposits, an Alternative in the Construction of Ag/AgCl Solid Elec...

Sequential Injection Spectrophotometric Determination of Diclofenac in Urine and Pharmaceutical Form...

Simultaneous determination of tetracyclines in poultry muscle by capillary zone electrophoresis

Development of a novel nitrate-selective composite sensor based on doped polypyrrole

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...

Chemical studies of anthocyanins: A review

Evaluación del contenido de metales y su efecto en la estabilidad de antocianinas

Determination of non-steroidal anti-inflammatory drugs in wastewaters by magnetic matrix solid phase...

Metal content evaluation and its effect on the stability of anthocyanins

Renewable stationary phase liquid magnetochromatography: determining aspartame and its hydrolysis pr...