Producción Científica Profesorado

Micro flow injection analysis of leucomalachite green in fish muscle using modified henequen fibers as microfluidic channels



Páez Hernández, María Elena

2021

T. Alexandra Ferreira, Alfredo Guevara-Lara,M. Elena Paez-Hernandez, Alicia C. Mondragon and Jose A. Rodriguez. Micro flow injection analysis of leucomalachite green in fish muscle using modified henequen fibers as microfluidic channels. RSC Adv., 2021,11, 35375-35382 https://doi.org/10.1039/D1RA06301D


Abstract


In this work a simple and novel procedure for leucomalachite green determination based on micro flow injection analysis (?FIA) with amperometric detection is presented. The method involves the use of henequen modified fibers as microfluidic channels. The ?FIA system proposed offers a simple, rapid, and low-cost alternative for the determination. Capillary and gravitational forces across the modified henequen fibers control the flow rate, eliminating the need for external pumps. This technique requires low reagent consumption and allows portability for in situ measurements. The flow system is described, and the operational variables were studied and optimized using a Taguchi parameters design to increase analytical sensitivity. Under optimal conditions a limit of detection of 1.16 ?g kg?1 was achieved with adequate repeatability and reproducibility (expressed as %RSD <5.0%, n = 3, n = 9 respectively) in all cases. The effect of interfering species and the accuracy of the method were also investigated. The proposed methodology was validated and applied to determine LMG in tilapia muscle samples.



Producto de Investigación




Artículos relacionados

Determination of oxytetracycline in milk samples by polymer inclusion membrane separation coupled to...

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...

Metal content evaluation and its effect on the stability of anthocyanins

Potentiometric behavior of graphite-epoxy electrochemical transducers towards anions, cations and pH...

Presence and antimicrobial resistance of Escherichia coli isolated from foodstuffs in Hidalgo State ...

Magnetic solid phase extraction based on phenyl silica adsorbent for the determination of tetracycli...

Determination of non-steroidal anti-inflammatory drugs in wastewaters by magnetic matrix solid phase...

Simultaneous determination of tetracyclines in poultry muscle by capillary zone electrophoresis

Evaluación del contenido de metales y su efecto en la estabilidad de antocianinas

Facilitated transport of Hg(II) through novel activated composite membranes