Producción Científica Profesorado

Electrochemical Determination of Pb(II) Using Carbon Paste Electrodes Modified with Ion Imprinted Polymers (IIPs).



Ibarra Ortega, Israel S.

2022

Luz E. Rebolledo, Giaan Arturo Álvarez Romero, Israel Samuel Ibarra-Ortega, Carlos Andres Galan-Vidal, Irma Pérez-Silva. (2022). Electrochemical Determination of Pb(II) Using Carbon Paste Electrodes Modified with Ion Imprinted Polymers (IIPs). ECS Transactions, 106, 21.


Abstract


An easy, low-cost, and highly selective carbon paste electrode based on an ion-imprinted polymer (IIP) to determine Pb(II) in real samples was developed. The recognition cavities based on a cross-linked polymer selective to Pb(II) were created using vinyl pyridine. The modified CPE was constructed by a composite mixture with the synthesized IIP. A notable difference was observed in the electrochemical response of the electrodes modified with the IIP and a non-imprinted polymer, demonstrating the unique properties of the IIP recognition sites. The parameters related to the current intensity were optimized; the selectivity was also studied considering potential interference ions. The proposed modified electrode demonstrated to be as (or more) selective to Pb(II) compared to others previously reported in the literature. A linear concentration range from 3.3 mg/L to 33 mg/L with a limit detection of 1 mg/L was obtained. The Pb(II) preconcentrated on the electrode surface was successfully quantified in real potable water samples without previous treatment.






Artículos relacionados

Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5...

Estudio de las Interacciones Ácido Húmico-Metales Pesados y Determinación de sus Constantes de Estab...

Prevalence and Antimicrobial Resistance Patterns of Salmonella from Different Raw Foods in Mexico

Determination of non-steroidal anti-inflammatory drugs in wastewaters by magnetic matrix solid phase...

High-performance liquid magneto-chromatography

Magnetic solid phase extraction based on phenyl silica adsorbent for the determination of tetracycli...

Validation of a tubular bismuth film amperometric detector: Determination of diclofenac sodium by mu...

Potentiometric behavior of graphite-epoxy electrochemical transducers towards anions, cations and pH...

Evaluación del contenido de metales y su efecto en la estabilidad de antocianinas

Development of a novel composite sensor based on doped pyrrole selective to nitrate ions