Producción Científica Profesorado

Selective removal of tetracycline residue in milk samples using a molecularly imprinted polymer.



Páez Hernández, María Elena

2020

Aguilar, J.F.F., Miranda, J.M., Rodriguez, J.A., Paez-Hernandez, M.E., Ibarra, I.S. Selective removal of tetracycline residue in milk samples using a molecularly imprinted polymer. Journal of Polymer Research. 2020, 27, 176. DOI: 10.1007/s10965-020-02139-9


Abstract


In the present work, the synthesis and characterisation of a molecularly imprinted polymer (MIP) by precipitation polymerisation using tetracycline (TC) as a template molecule, methacrylic acid as a functional monomer, ethylene glycol dimethacrylate as a cross-linker, persulphate as an initiator, and methanol as a porogen solvent is described. The molecular recognition properties and selectivity of MIPs against four TCs [(TC), oxytetracycline (OT), chlortetracycline (CT), and doxycycline (DT)] were evaluated, and the results demonstrated high selectivity for four TCs in milk samples without sample treatment. Under the optimal synthesis conditions (TC/methacrylic acid/ethylene glycol dimethacrylate ratio of 1.0:7.0:50.0), the percent removal obtained was 81.83% for TC, 95.47% for OT, 96.44% for CT, and 93.25% for DT using 1.0 mL of the sample, 20 mg of the sorbent, a pH of 6.0, and 15 min of contact time. One of the tested samples was positive for the presence of OT, with a concentration of 19.83 ?g L?1, ensuring the complete removal of TC using the proposed method. The method provided significant data regarding the development of efficient and selective materials in the removal of several residues and contaminants



Producto de Investigación




Artículos relacionados

Estudio de las Interacciones Ácido Húmico-Metales Pesados y Determinación de sus Constantes de Estab...

Design and Construction of Solid State Ag/AgCl Reference Electrodes Through Electrochemical Depositi...

Magnetic solid phase extraction based on phenyl silica adsorbent for the determination of tetracycli...

Validation of a tubular bismuth film amperometric detector: Determination of diclofenac sodium by mu...

Evaluación del contenido de metales y su efecto en la estabilidad de antocianinas

Influence of the Cation Nature of the Sulphate Salt on the Electrochemical Synthesis of Sulfate-Dope...

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...

Chemical studies of anthocyanins: A review

Multicommutated Anodic Stripping Voltammetry at Tubular Bismuth Film Electrode for Lead Determinatio...

Facilitated transport of Hg(II) through novel activated composite membranes