Size exclusion chromatography (SEC-HPLC) as an alternative to study thrombin inhibition, Pérez-Escalante, E., González-Olivares, L.G., Cruz-Guerrero, A.E., Galán-Vidal, C.A., Páez-Hernández, M.E., Álvarez-Romero, G.A., Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 1074-1075 (2018) 34-38, DOI: 10.1016/j.jchromb.2017.12.037


Abstract


In vitro analysis of anticoagulant compounds with a potential use as antithrombotic drugs, has been traditionally performed using techniques like spectrophotometry, turbidimetry, as well as electrochemical and clinical assays. Although, these techniques have some disadvantages such as: the inability to measure the total biological activity of thrombin, interferences and, sometimes, the quantitative determination of the inhibition ratio is not accurate. In the present work, the conversion of fibrinogen to fibrin was monitored by molecular exclusion chromatography (SEC-HPLC) in three different reaction systems. An inhibition percentage of 43.192.02% was obtained using heparin as an anticoagulant, in addition to the determination of the percentage of heparin bonded to thrombin. This methodology has not been previously described and has high potential for the determination of anticoagulant capacity with higher precision, the determination of thrombin's total biological activity and the quantitative determination of the inhibition ratio



Producto de Investigación




Artículos relacionados

Cobalt Electrodeposition Process from Electrolytic Baths based on CoSO4 and (NH4)2SO4. Influence of ...

Theoretical and Experimental Study of Cobalt Nucleation and Growth onto Gold Substrate with Differen...

Quantum chemical study of the electrochemical reduction of the [Co(H2O)6]2+ and [Co(NH3)5(H2O)]2+ io...

Analysis of the experimental pressuretemperature behavior in the isotropicnematic phase transition f...

Cobalt electrodeposition onto highly oriented pyrolytic graphite (HOPG) electrode from ammonium sulf...

Kinetic study of the cobalt electrodeposition onto glassy carbon electrode from ammonium sulfate sol...

Mercury Ions Removal from Aqueous Solution Using an Activated Composite Membrane

Evaluación de Esteroides Aromáticos como Indicadores de Madurez Térmica en Extractos de Roca

Revisión de variables de diseño y condiciones de operación en la electrocoagulación

Hydrogen bond studies in substituted N-(2-hydroxyphenyl)--2-[(4-methylbenzenesulfonyl)amino]acetamid...